kopfbild

EN 12326 - Thermal cycle test

With this test it is possible to make statements about the resistance of a slate against weathering.

 

Code Observation
T 1 no alteration of the appearance
oxidation of the surface of metallic minerals
alteration of the colour which neither influence the structure of the slate nor build areas of discolouration
T 2 oxidation or alteration of the appearance of metallic components with discolouration areas but without alteration of the structure
T 3 oxidation or alteration of the surface of metallic components which penetrate the slate and could cause holes.

Demands in regard to the Thermal cycle

 

Slates which show splitting, flaking off or other striking structural alterations are not permissible. T3 - slates which possibly become permeable to water, should be used only occasionally with special techniques of laying which prevent the penetration of water.